GENERAL SPECIFICATIONS :
Power supply : 230Vac +-10%, 50Hz – maximum
protection 16A/2P .
This device is exclusively suitable for DIN-rail
mounting EN50022.
Insulation voltage : 3 kVac tested
Characteristic consumption : 4.5VA
Ambient temperature :
Working temp. range : 10°C to 70°C
Storage temp. range : -10°C to 70°C
Maximum humidity : 93%, no moisture
condensation
Bus load : 10mA at nominal 13,8V
Fuse : 500mAT single-phase
Max installation altitude : 2000meters
OUTPUTS :
1 – 4 : dimmable outputs for halogen, incandescent,
dimmable 230V LED and dimmable CFL lamps. Maximum load :
Incandescent / halogen with electronic transfo: max
500VA at 230Vac each circuit
Halogen with classic (magnetic) transfo max
400VA at 230Vac each circuit
4 OUTPUTS 10-500VA, 5 INPUTS UNIVERSAL RELAY MODULE
The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.
Your custom content goes here. You can add the content for individual product
Related products
In a Qbus system, motor control (for shutters, screens,…) can be done centrally (from the electrical distribution board) or decentrally (with a module on the bus closeby the motor).
2 OUTPUTS 8AMP. 2 IINPUTS SHUTTER MODULE
Via the relay modules, outputs can be switched. A relay module has no specific function but can handle any switch functions: monostable (eg a doorbell), bistable (on / off), timer, interval, thermostat output. Some relays can also control motors of blinds, curtains, gates.
RELAY MODULE (4X 16A)
Module which counts and processes pulses received from a pulse meter. Any pulse meter can be connected to the ECM04 as long as the contacts are potential-free. The ECM04 can receive a pulse every 250ms. Alarms can be triggered based on a set number of pulses, for example to receive green energy certificates every kW generated by solar panels.